222 UVC Australia - Far UVC Lights

UV222 Hybrid-Linear

This LED Batten light is equipped with four UV222 excimer lamps.


Thus providing white light illumination and UV sanitation in one compact and versatile fitting.

The Hybrid-Linear has been developed and specifically engineered at the request of surgeons to reduced the rate of Surgical Site Infections.

As such these lights are used in operating rooms to illuminate the operating zone and similitaneously sanitise the air and exposed instruments and contact surfaces.

This hybrid light can also be used many other areas where lights for illumination and sanitation is required, such as emergency departments, waitig rooms, wards, common areas in aged-care homes, offices, restaurants, etc....



Specifications

UV

UV Light source Krypton chloride excimer lamp
Wave length 222 nm
UV Output (60° beam angle) 115 mW (Typical)
Operating modes Continuous / duty cycle / motion activated
Power consumption UV light 17 W
UV Lamp lifespan 17,000 hrs

LED

Cyanosis Observation Index (COI) approval AS/NZS 1680.2.5:2018
Colour temperature 4,000 K
Useful luminous flux 2,118 lm at Irated and tp = 25°C
High colour rendering index >90
Power consumption 38 W
LED lifespan 72,000 hrs

FITTING

Dimensions 60 mm x 59 mm x 999 mm (Custom lengths available on special order)
Weight 2.3 kg
Max. Total power consumption 60 W
Input voltage 85-264V AC 50/60 Hz
Power cord 3 x 0.75 mm² / 5 m² / Nylon
Operating temperature 0° to + 40° C

Beam Angle


The Hybrid-Linear is available with in only a 60° beam angle format.




Light measurement results


Parameter 60° beam angle
Total optical flux, 200nm – 850nm 126.92 mW
Far UV-C 200nm – 230nm 120.79 mWn
VIS-IR: 400nm – 850nm 6.81 mW
Radiated power/lamp power 0.926 %
Peak emission wavelength 222 nm
222 nm) irradiance at centre at 1 m 13.8 μW/cm2

Photometrics and exposure time for SARS-CoV2


The spatial and spectral distribution of the light is measured on each lamp using a 2-axis goniometer giving the entire 3D distribution of the Far UV-C light emitted by it.


60° beam angle
Peak emission wavelength: 222 nm Output power in range (200-230 nm): 115 mW Dose needed (222 nm, COVID-19) 90% inactivation for aerosols: 390 μJ/cm2 Dose needed (222 nm, COVID-19) 90% inactivation for surfaces: 600 μJ/cm2




Wavelength

🔴 UV222 Far UV-C excimer lamp with an optical band-pass filter

🟢 A typical krypton chloride 222 nm Far UV-C excimer lamp without an optical band-pass filter

WARNING!
Unfiltered Far UV-C can cause cancer and may increase the risk of cataracts.