222 UVC Australia - Far UVC Lights

UV222 Cleanroom Downlight

Minimise the risk of contamination in cleanrooms

Cleanroom standards outline stringent requirements, dictating the particle and microbial load tolerances for grade D to A cleanrooms. Cleanroom operators are trained to navigate these highly restricted environments. Additionally, specialised ventilation systems are engineered to deliver filtered airflow. These combined efforts reduce the risk of particle contamination in the production area.

Incorporating the UV222 Cleanroom Downlight into cleanrooms continuously reduces the microbial load resulting from operator activities, diminishing the overall risk of contamination.

The UV222 Cleanroom Downlight is easily integrated in pre-existing cleanrooms, offering effective and chemical-free air and surface decontamination. Its circular design ensures a perfect fit into industrial ceilings.




Designed for cleanrooms

The UV222 Cleanroom Downlight meets all cleanroom installation requirements up to class A/B. This includes the need for a primary seal, which can be inspected and replaced every 5 years for maintenance.

The front module of the lamp is oriented towards the cleanroom area, serving as a ceiling insert that seamlessly fits various types of ceiling panels. It is powder-coated, and features quartz glass bonded and sealed to the ceiling panel using FDA-approved silicone. To access the lamp for maintenance, the back module can be unscrewed.

Furthermore, the entire lamp is certified IP66, dust-tight, and complies with ATEX directives for added safety and reliability



Specifications


Light source Krypton chloride excimer lamp
Wave length 222 nm
Output (60° beam angle) 115 mW (Typical)
Output (100° beam angle) 70 mW (Typical)
Operating modes Continuous / duty cycle / motion activated
Operating temperature 0° to + 50° C
Input voltage 85-305V AC 50/60 Hz
Max. power consumption 17 W
Weight 1.6 kg
Dimensions Ø 236 mm x 100 mm
Power cord 3 x 0.75 mm² / 5 m² / Nylon
Lamp lifespan 17,000 hrs

Beam Angle


UV222 is available on both 60° and 100°, but every lamp is measured after production and sent with its unique specifications report.




Light measurement results


Parameter 60° beam angle 100° beam angle
Total optical flux, 200nm – 850nm 126.92 mW 75.72 mW
Far UV-C 200nm – 230nm 120.79 mWn 58.79 mW
VIS-IR: 400nm – 850nm 6.81 mW 10.71 mW
Radiated power/lamp power 0.926 % 0.57 %
Peak emission wavelength 222 nm 222 nm
222 nm) irradiance at centre at 1 m 13.8 μW/cm2 3.2 μW/cm2

Photometrics and exposure time for SARS-CoV2


The spatial and spectral distribution of the light is measured on each lamp using a 2-axis goniometer giving the entire 3D distribution of the Far UV-C light emitted by it.


60° beam angle 100° beam angle
Peak emission wavelength: 222 nm Output power in range (200-230 nm): 115 mW Dose needed (222 nm, COVID-19) 90% inactivation for aerosols: 390 μJ/cm2 Dose needed (222 nm, COVID-19) 90% inactivation for surfaces: 600 μJ/cm2 Peak emission wavelength: 222 nm Output power in range (200-230 nm): 70 mW Dose needed (222 nm, COVID-19) 90% inactivation for aerosols: 390 μJ/cm2 Dose needed (222 nm, COVID-19) 90% inactivation for surfaces: 600 μJ/cm2




Wavelength

🔴 UV222 Far UV-C excimer lamp with an optical band-pass filter

🟢 A typical krypton chloride 222 nm Far UV-C excimer lamp without an optical band-pass filter

WARNING!
Unfiltered Far UV-C can cause cancer and may increase the risk of cataracts.



Dimensions

Ø 236 mm

Height = 100 mm

UV222 Downlight is designed to be integrated on any secondary ceiling capable of holding its weight, only needing an circular opening between 215 to 225 mm.